Operationis principium a Plasma Cleaner

Jul 03, 2025

Plasma cleaners use plasma discharge to generate a high-energy oxidation reaction. Using oxygen or a mixed gas (such as oxygen + hydrogen) in the discharge zone, they form an ion plasma (energy range 5-15 eV). The high-energy electrons and radiation from these plasmas decompose surface contaminants (organic matter oxidation rate >90%), gaseosa vel solutum producta producens. Haec technologia chemicam- liberam, non- contactum purgandum praebet, ad curationem superficierum metallorum (ut ferrum immaculatum et aluminium) et polymerorum (ut PTFE) et polymerorum (ut PTFE) idoneus praebet, et praecipue bene - ad curationem electronicarum partium et ad medicinas curandas aptus est.

Secundum efficientiam purgatio, typica curatio tempora ab 2-10 minutes per batch vagantur. Potest removere contaminantium nanoscale (particula magnitudine<100 nm), reduce surface contact angles by over 40°, and significantly improve material adhesion. Important operating parameters: maintain power between 50-1000W, air pressure between 10-100 Pa, and avoid overheating the substrate (temperature <150°C).